Please contact info@teamengineers.in
FABIO-4CS-RE Integrating Access Device (IAD) with Auto Changeover , Quad Health Status , DSL built-in (Digital Axle Counter,UFSBI,SCADA-RTU,Datalogger etc.)
Teamlink FABIO-4CS-RE helps in interfacing with ITU-T V.21/V.23(BPAC/DAC/UFSBI/Data logger/RTU etc.) to connect to E1 (IPMPLS / STM) or optical 1+1 channel it is most suitable for Indian Railways signaling/Telecommunication / SCADA applications like digital axle counter / UFSBI / Interconnection, voice communication, ethernet communication of SCADA. The equipment has multiple auto -change over facility allows automatic diversion of critical traffic to the available stand – by copper circuits or DSL line when the E1 or Optical link fails. Critical events reporting enables immediate resolution of the problem though data logger potential free contacts the unit is available range power supply in 18VDC to 72 VDC, 110 VDC, 230 VAC redundant power supply
FABIO-4CS-RE is a modular integrated access device (IAD) with cross connect ability which integrates multiple dedicated data, voice, and LAN channels over multiple main network links. it provides E1 , Optical uplink integrated in a single device and multiple tributary and fixed tributary such as Ethernet ( IP Surveillance , Fire alarm , SCADA -RTU ) , Voice (FXS , FXO and combine module of FXS – FXO ) , E&M ( dedicated channels and with auto change over ) , RS 232 , RS442, V.21/ V.23 for integrating various critical circuits of Indian Railways over the SDH or IPMPLS network . IAD is ruggedized and uses high quality chipsets suitable for various environments.
FABIO-4CS-RE enables carriers / Indian Railway / Defence etc., to successfully deploy critical bundled services over their SDH, IPMPLS, SDN network or on dedicated optical fibre, the unit helps to integrated legacy, current interfaces dedicated optical fibre or E1 in a seamless cost-effective manner. The equipment conforms to International standards ensuring compatibility in multivendor enjoinment worldwide.
FABIO-4CS-RE is designed in India and manufactured and as some very unique features to help Indian Railways to increase the reliability of their critical circuits and saving quad between stations and locations which is a huge benefit for numerous reasons and allowing Indian Railways to seamlessly migrate to a complete optical connectivity
FABIO-4CS-RE is designed to carry Various Original Equipment Manufacturer’s Digital Axle Circuits over optical fiber (STM).
Automatic Changeover to bypass copper (QUAD) circuit if E1 / Optical link fails or FABIO-4CS-RE unit is powered OFF
Event log Facility is provided E1, V.21 and Optical extra
The bypass copper (QUAD) circuit is constantly checked for availability as long as the E1 / Optical Link is UP
Potential Free Alarm Relay Contacts for Local and Remote monitoring or these relay contacts may be connected to a Data Logger for centralised monitoring of these alarms
Compact 1U high, 19-inch chassis
Max. E1 channels : : 2 Electrical and 2 Optical E1s
Frame structure : : Supports optional CRC-4 and PCM 30/31 settings.
Timing : : Internal Crystal Oscillator clock, Clock received from any link (loopback)
Versatile 64Kbps User interface : : E&M 2/4-wire module with adjustable voice gain, Quad Cable Ports and V.24/RS-232 low speed Ports and 4Ethernet
Optical 1+1 155Mbps Interface :
Max E&M channels : : 6 (2W/4W)
Quad Ports : : 6
Async / V.24 Ports : : 2 over optical
Max FE channels : : 4 over optical
Performance Monitor : : Control panel provides ample control and alarm function. When an E1 channel occurs errors, sound alarm will be activated and LOS/LOF warning message of each E1 channel will be displayed.
Customer service can be allocated by on-line network operator.
Flexible network topologies : : Point-to-Point , Daisy Chain
Local and Remote Telnet support.
Realtime Clock setting for Monitoring the Signals and creating the Log File for the E1 UP and DOWN events as well as Copper UP and DOWN Events.
Potential Free contacts for indicating the events E1 Link UP, E1 Link DOWN, V.21 Signal UP and DOWN between two axle counters.
Resettable buzzer to draw attention in case E1 or OFC Link Fails
I/O modules : 2 Electrical and 2 optical E1’s and 6 E&M 2W/4W, 6 Quad Cable Ports 2/4W, 2 RS232/V.24, 4ETH Ports 4 Potential Free Contacts for extending alarms
Chassis(height) : 1U, 19-inch wide
Console port : 1 (RJ-45), Serial
Telnet port : 10/100Mbps (RJ-45), Ethernet
Line type : 2 or 4 Wire (twisted pair operation) Configurable
Line Code : TCPAM as per the ITU-T G991.2
Line Impedance : 135 Ohms
Connector : RJ45
Transmit Signal Power up to : 16.8dBm
Line protection : As per ITU-T K20 and K21
Specification : ANSI T1.601
Distance : Supports Various Rate-Range Configurations
Number of Ports : Six 2W/4W Selectable
Connector : RJ45
Channel sampling rate : 8 KHz
Companding law : A-law
Voice Interface : 2W, 4W, Signalling, E&M
Frequency : 300 to 3400 Hz
Impedance : 600 Ohms
Number of Ports : Two
Low speed data interface : RS232, V.24
Characteristic : ITU-T V.24
Data Format : Asynchronous
Asynchronous data : Auto baud upto 115.2 Kbps
Number of Ports : Four
Compliance : IEEE 802.3
Speed : 10/100 Mbps High speed
Supports Auto MDI / MDIX
Auto Negotiation as per 802.3x
Supports Half / Full Duplex Flow control
Number of contacts : 4
Potential Free Contacts for extending alarms
The Device will Facilitates the E1 Link DOWN E1 LINK UP, Individual Quad Status, Power OFF, OFC Link alarms
Bypass Link Monitoring or Copper Link Monitoring.
Supports 512×512 cross connect ability based on 64K with signaling
Number of Ports : 2
Bit rate : 2048 +/- 50 ppm
Code : HDB3
Impedance : 120 Ohms Balanced
Electrical characteristics : ITU-T G.703
Transfer characteristics : ITU-T G.823
Jitter performance : ITU-T G.823
TEAMLINK FABIO-4CS-RE will records the events Link E1 UP, E1 DOWN, QUAD UP, QUAD down conditions in the flash so even the Power Goes OFF also we can monitor the events after the Power comes.
Changing the RTC clock timing is using the menu driven program.
E1 Line Error Rate Monitoring Log.
Power, E1 UP, E1 DOWN, QUAD UP, QUAD DOWN, OPTICAL UP, OPTICAL DOWN, 2/4 Wire Mode
V.21 working Line status, E1 ERROR status
10FXS Interface Card
10FSO Interface Card
8 Number of 2 wire or 4 Wire E&M Interface Card
2 E1 Interface RSTP card for the SCADA applications
2 Port Ethernet Interface card which will supports up to 2Mbps speeds on the WAN Interface either in E1 channel or Optical channel.
RS232 Card which will supports 8 channels with the 9.6Kbps / 19.2 Kbps speeds.
Single channel RS422, RS485 or RS232 Card which will supports up to 230Kbytes of speeds
4 Port E&M channel with the auto media change over facility which will switch the E&M channel (V.21 / V.23) From E1/ Optical E1 interface to the QUAD mode in less than 5 milli seconds.
Feeding voltage -48V
Loop current is 20milli amps
TIP / RING Reversal checking
Ringing voltage 65vrms
Return Loss 16dB at 300-500Hz
Tip Ring Reversal Setting time is 50 milli seconds
Connector Type RJ45 Interface
Return Loss 16dB at 300-500Hz
Tip Ring Reversal Setting time is 50 milli seconds
Return loss 600Ohms is 18 to 35dB.
ON hook reception
Transformer isolation providing the high common-mode rejection CMRR for use in un grounded systems.
Connector Type RJ45 Interface
Supports 2 wire and 4 wire channel configurations.
2 wire / 4 wire selection is software configurable not required to plug out the interface card.
E and M signals transmission for each channel
50 pin SCSI Female connector
50Pin SCSI Male connector with the cable is provided for connecting the E&M channels.
Supports 2 wire and 4 wire channel configurations.
2 wire / 4 wire selection is software configurable not required to plug out the interface card.
E and M signals transmission for each channel
Switching from network interface E1 / Optical to the QUAD is for each channel
Switching time is less than 5 milli seconds.
QUAD interface health checking.
Each E&M channel present working interface LED indication E1/Optical / QUAD
Number of ports 1
Supports 9.6Kbps to 230 kbps
Supports 2 E1 interface
2 E1 Interfaces can be connected to two different directions for SCADA.
Logical ethernet interface with the RSTP facility
Each E1 Link UP and the DOWN checking.
Routing the SCADA interface traffic on working E1 Interface.
Supports UNFRAMED/FramedPCM31/PCM30 Operations.
Supports HDLC and GFP on E1 interface
Compatible with the Teamenginners standalone E1 to ethernet converter.
Number of the Ethernet interfaces three
Supports RSTP protocol on this ethernet interfaces
STP and RSTP as per the IEEE802.w, IEEE802.d
Supports up to 2Mbps speeds on E1 / Optical logical interface in steps of 64Kbps speeds
Number of ports 8
Supports 9.6Kbps to 19.6 kbps on each timeslot and if 2 timeslots are configured for each RS232 port then the baud rate will
support upto115.2kbps speeds.
In case the power to device is OFF The individual V.21/V.23 channel will automatically shift to Quad Without affecting end -to- end communication
The Front Panel Supports 2W Quad Health Status, the Quad Connected heath is monitored when that particular Port is working On E1 or OFC , the status can also be Linked to data logger. If the Errors in the Quad increase beyond a threshold -30db an alarm can be trigger through Potential free contacts
DC : -18V ~ -72V (nom : -48V DC) redundant available / AC : 100V ~ 240V AC (220V nom) DC to AC adaptor
Operating Temperature : -5 to +55°C
Operating Humidity : 5% to 90 %
To TEC QM333 Environmental Standard tested in NABL accredited LAB
FABIO-4CS-RE series devices are suitable for disaster communication for extending various services to mid-section in Indian Railways
The unit is configurable vide Console / Telnet with built-in user friendly menu driven application and does not require any additional software, unit can be configured by using any PC or LAPTOP available.
Event log Facility is provided
Local and Remote Telnet support
Supports Various Rate-Range Configurations
Supports 512×512 cross connect ability based on 64K with signaling
E1 Line Error Rate Monitoring Log.
Compact 1U high, 19-inch chassis
Eth data interface Speed : 10/100 Mbps
Supports Half / Full Duplex Flow control
SHDSL Interface Line type 2 or 4 Wire