Teamlink FABIO-2CX helps in interfacing the attached devices with ITU-T V.21/V.23 to connect to E1 or Optical 1+1 channel. It is most suitable for Indian Railway Signaling Applications like Axle Counter/UFSBI Inter-connection. The equipment's auto-change over facility allows automatic diversion of V.21/V.23 traffic to the available stand-by Copper circuit when the E1 or Optical link fails. Critical events reporting enables immediate resolution of the problem. The unit is available in 18 V DC to 72V DC redundant power supply.
FABIO-2CX is a modular integrated Access TDM multiplexer with cross connect ability, which integrates multiple dedicated data, voice and LAN channels over multiple main (network) links. It can provide maximum 2 Electrical and 2 optical E1’s and 2W/4W E&M, Quad Cable Ports, RS232/V.24, ETH capacity for accessing and transmission with cross-connect capacity is 512×512 64K. It provides full range of voice and digital data services to subscribers located at different locations require to interconnect and establish a voice and data network over E1 link or optical.
FABIO-2CX enables carriers to successfully deploy bundled services and Internet access. The integration of a broad range of services makes FABIO-2CX a cost-effective access device, with reduced deployment and maintenance costs. The equipment conforms to international standards, ensuring compatibility in multi-vendor environments worldwide.
FABIO-2CX is designed to carry Various Original Equipment Manufacturer’s Digital Axle Circuits over optical fiber (STM).
Automatic Changeover to bypass copper (QUAD) circuit if E1 / Optical link fails or FABIO-2CX unit is powered OFF
Event log Facility is provided E1, V.21 and Optical extra
The bypass copper (QUAD) circuit is constantly checked for availability as long as the E1 / Optical Link is UP
Potential Free Alarm Relay Contacts for Local and Remote monitoring or these relay contacts may be connected to a Data Logger for centralised monitoring of these alarms
Compact 1U high, 19-inch chassis
Max. E1 channels : 2 Electrical and 2 Optical E1s
Frame structure : Supports optional CRC-4 and PCM 30/31 settings.
Timing : Internal Crystal Oscillator clock, Clock received from any link (loopback)
Versatile 64Kbps User interface : E&M 2/4-wire module with adjustable voice gain, Quad Cable Ports and V.24/RS-232 low speed Ports and 4Ethernet.
Optical 1+1 155Mbps Interface .
Max E&M channels : 6 (2W/4W).
Quad Ports : 6 .
Async / V.24 Ports : 2 over optical .
Max FE channels : 4 over optical .
Performance Monitor: Control panel provides ample control and alarm function. When an E1 channel occurs errors,
sound alarm will be activated and LOS/LOF warning message of each E1 channel will be displayed.
Customer service can be allocated by on-line network operator.
Flexible network topologies : Point-to-Point , Daisy Chain.
Local and Remote Telnet support.
Realtime Clock setting for Monitoring the Signals and creating the Log File for the E1 UP and DOWN events as well as Copper UP and DOWN Events.
Potential Free contacts for indicating the events E1 Link UP, E1 Link DOWN, V.21 Signal UP and DOWN between two axle counters.
Resettable buzzer to draw attention in case E1 or OFC Link Fails
I/O modules :2 Electrical and 2 optical E1’s and 6 E&M 2W/4W, 6 Quad Cable Ports 2/4W, 2 RS232/V.24, 4ETH Ports 4 Potential Free Contacts for extending alarms.
Chassis(height) : 1U, 19-inch wide.
Console port : 1 (RJ-45), Serial
Telnet port : 10/100Mbps (RJ-45), Ethernet
Number of Ports : Six 2W/4W Selectable.
Connector : RJ45.
Channel sampling rate: 8Khz
Commanding law : A-Law
Voice Interface : 2W, 4 W Signaling E&M
Frequency : 300 to 3400Hz
Impedance : 600Ohms
Number of Ports : 2.
Low speed data interface : RS232, V.24
Characteristic : ITU-T V.24
Data Format : Asynchronous.
Asynchronous data : upto 115.2 Kbps.
Number of Ports : 4.
Compliance : IEEE 802.3
Speed : 10/100 Mbps High speed.
Supports Auto MDI / MDIX.
Auto Negotiation as per 802.3x.
Supports Half / Full Duplex Flow control.
Number of contacts : 4.
Potential Free Contacts for extending alarms.
The Device will Facilitates the E1 Link DOWN E1 LINK UP, Individual Quad Status, Power OFF, OFC Link alarms.
Bypass Link Monitoring or Copper Link Monitoring.
Supports 512×512 cross connect ability based on 64K with signaling
Bit rate : 2048 +/- 50 ppm
Code : HDB3
Impedance : 120 Ohms Balanced
Electrical characteristics : ITU-T G.703
Transfer characteristics : ITU-T G.823
Jitter performance : ITU-T G.823
TEAMLINK FABIO-2CX will records the events Link E1 UP, E1 DOWN, QUAD UP, QUAD down conditions in the flash so even the Power Goes OFF also we can monitor the events after the Power comes.
Changing the RTC clock timing is using the menu driven program.
E1 Line Error Rate Monitoring Log.
Power, E1 UP, E1 DOWN, QUAD UP, QUAD DOWN, OPTICAL UP, OPTICAL DOWN, 2/4 Wire Mode.
V.21 working Line status, E1 ERROR status.
10FXS Interface Card.
10FSO Interface Card.
8 Number of 2 wire or 4 Wire E&M Interface Card.
2 E1 Interface RSTP card for the SCADA applications.
2 Port Ethernet Interface card which will supports up to 2Mbps speeds on the WAN Interface either in E1 channel or Optical channel..
RS232 Card which will supports 8 channels with the 9.6Kbps / 19.2 Kbps speeds..
Single channel RS422, RS485 or RS232 Card which will supports up to 230Kbytes of speeds.
4 Port E&M channel with the auto media change over facility which will switch the E&M channel (V.21 / V.23) From E1/ Optical E1 interface to the QUAD mode in less than 5 milli seconds..
Feeding voltage -48V.
Loop current is 20milli amps.
TIP / RING Reversal checking.
Ringing voltage 65vrms.
Return Loss 16dB at 300-500Hz.
Tip Ring Reversal Setting time is 50 milli seconds.
Connector Type RJ45 Interface.
Return Loss 16dB at 300-500Hz.
Tip Ring Reversal Setting time is 50 milli seconds.
Return loss 600Ohms is 18 to 35dB.
ON hook reception.
Transformer isolation providing the high common-mode rejection CMRR for use in un grounded systems.
Connector Type RJ45 Interface.
Supports 2 wire and 4 wire channel configurations.
2 wire / 4 wire selection is software configurable not required to plug out the interface card.
E and M signals transmission for each channel.
50 pin SCSI Female connector.
50Pin SCSI Male connector with the cable is provided for connecting the E&M channels.
Supports 2 wire and 4 wire channel configurations.
2 wire / 4 wire selection is software configurable not required to plug out the interface card..
E and M signals transmission for each channel.
Switching from network interface E1 / Optical to the QUAD is for each channel.
Switching time is less than 5 milli seconds.
QUAD interface health checking.
Each E&M channel present working interface LED indication E1/Optical / QUAD.
Supports 2 E1 interface.
2 E1 Interfaces can be connected to two different directions for SCADA..
Logical ethernet interface with the RSTP facility.
Each E1 Link UP and the DOWN checking.
Routing the SCADA interface traffic on working E1 Interface.
Supports UNFRAMED/FramedPCM31/PCM30 Operations.
Supports HDLC and GFP on E1 interface.
Compatible with the Teamenginners standalone E1 to ethernet converter.
Number of the Ethernet interfaces three.
Supports RSTP protocol on this ethernet interfaces.
STP and RSTP as per the IEEE802.w, IEEE802.d.
Supports up to 2Mbps speeds on E1 / Optical logical interface in steps of 64Kbps speeds.
Number of ports 8 .
Supports 9.6Kbps to 19.6 kbps on each timeslot and if 2 timeslots are configured for each RS232 port then the baud rate will support upto115.2kbps speeds.
Number of ports 1.
Supports 9.6Kbps to 230 kbps.
In case the power to device is OFF The individual V.21/V.23 channel will automatically shift to Quad Without affecting end -to- end communication.
The Front Panel Supports 2W Quad heath Status, the Quad Connected heath is monitored when that particular Port is working On E1 or OFC , the status can also be Linked to data logger. If the Errors in the Quad increase beyond a threshold -30db an alarm can be trigger through Potential free contacts.
DC : -18V ~ -72V (nom : -48V DC) redundant available / AC : 100V ~ 240V AC (220V nom) DC to AC adaptor
Operating Temperature : -5 to +55°C
Operating Humidity : 5% to 99%
To TEC QM333 Environmental Standard tested in NABL accredited LAB
FABIO-2CX series devices are suitable for disaster communication for extending various services to mid-section in Indian Railways
The unit is configurable vide Console / Telnet with built-in user friendly menu driven application and does not require any additional software, unit can be configured by using any PC or LAPTOP available.
Telnet port : 10/100Mbps (RJ-45), Ethernet
Number of Ports : Six 2W/4W Selectable
Connector : RJ45
Frequency : 300 to 3400Hz
Data Interface: Number of Ports-2
Eth Data Interface: Number of Ports- Four
Speed : 10/100 Mbps High speed
Bit rate : 2048 +/- 50 ppm
Supports 2 wire and 4 wire channel configurations.